Septic System Pumping

Traditionally, the most common domestic wastewater treatment system used in rural areas is the septic tank-soil absorption system. The septic tank removes settleable and floatable solids from the wastewater. The soil absorption field then filters and treats the clarified septic tank effluent and distributes it through the soil. Removing the solids from the wastewater protects the soil absorption system from clogging and failure. In addition to removing solids, the septic tank also promotes biological digestion of a portion of the solids and stores the remaining undigested portion.

The first stage of the treatment system, the septic tank, removes solids by holding wastewater in the tank. This allows the heavier solids to settle as sludge and the lighter particles to form scum at the top. To accomplish this, wastewater should be held in the tank for at least 24 hours. Up to 50 percent of the solids retained in the tank decompose; the remainder accumulates in the tank. Biological and chemical additives are not needed to aid or accelerate decomposition.

As the system is used, sludge continues to accumulate in the bottom of the septic tank. Properly designed tanks should have enough space for up to three years safe accumulation of sludge. When the sludge level increases beyond this point, sewage has less time to settle before leaving the tank and more solids escape into the absorption area. If too much sludge accumulates, no settling occurs before the sewage flows to the soil absorption field. Infiltration of sludge into the soil absorption field can cause system failure. To prevent this, the tank must be pumped periodically. The material pumped is known as septage.

The frequency of pumping depends on several factors:
1.capacity of the septic tank
2.volume of wastewater (related to size of household)
3.amount of solids in wastewater (e.g. garbage disposals produce more solids)
Table I lists estimated pumping frequency according to septic tank capacity and household size. The frequencies were calculated to provide a minimum of 24 hours of wastewater retention assuming 50 percent digestion of the retained solids.

TABLE 1 Estimated septic tank pumping frequencies in years
(for year-round residences)

Tank Household size (number of people)
Tank Size 1 2 3 4 5 6 7 8 9
gals. (Years between pumping listed below)
500 6.0 2.5 1.5 1.0 0.5 0.5 0.3 0.2 0.1
750 9.0 4.0 2.5 2.0 1.5 1.0 0.5 0.5 0.5
900 11.0 5.0 3.5 2.5 1.5 1.5 1.0 1.0 0.5
1000 12.5 6.0 3.5 2.5 2.0 1.5 1.0 1.0 1.0
1250 15.5 7.5 5.0 3.5 2.5 2.0 1.5 1.5 1.0
1500 19.0 9.0 6.0 4.0 3.5 2.5 2.0 2.0 1.5
1750 22.0 10.5 7.0 5.0 4.0 3.0 2.5 2.0 2.0
2000 25.5 12.5 8.0 6.0 4.5 3.5 3.0 2.5 2.0
2250 28.5 14.0 9.0 6.5 5.0 4.0 3.5 3.0 2.5
2500 31.9 15.5 10.0 7.5 6.0 5.0 4.0 3.5 3.0



* Below the minimum size allowed by rule.

Note: More frequent pumping is needed if a garbage disposal is used. Generally the indicated frequency will vary with the volume of solids (+20% for high volume, -20% for low volume). Also, more frequent pumping will be needed if your tanks are not water tight, and allow the infiltration of storm or ground water.



Previous Article : Drip Septic System - - Next Article : Carbon Filters

Featured Articles
Providing Quality Service...Guaranteed In the Greater Austin Area of Travis, Hays, Williamson, Burnet, & Bastrop Counties , Briarcliff, Jollyville, Onion Creek, WoodCreek, Driftwood, Buda.
Call (512) 338-1804 for fast, dependable service.
Seller Says "Too Bad" Seller Says “Too Bad” After Homebuyers Find Rotting Septic Tank Under Plywood (From Pumper Magazine, October 23, 2018) A news organization in Cortland Manor,...
Alternative Septic System Regarding your Home Aerobic Treatment Unit: The components in your home plant should be serviced at least twice per year. The tanks must be...
Unhappy With Your Septic System? Why do so many customers end up dissatisfied with their septic systems? We feel it starts with nobody asking or even considering the owner's opinion before...
  • Septic Concrete Quality control testing for compressive strength of cylindrical concrete specimens must be performed and recorded on test cylinders...
  • Carbon Filters Noxious gases are generated naturally as part of the biological activity in septic tanks. Puffs of these odorous...
  • Septic System Service Planned Service AgreementsSnowden Onsite Septic, Inc. (SOS) is able to offer a better approach to service that can...
  • Costs Septic When a person buys a house, car, computer or almost anything of any complexity, there are always upgrades...
  • Field Leach Septic System There are three reasons why septic system maintenance is important to you and your community. 1.The first is...